39 research outputs found

    Electrical Advantages of Dendritic Spines

    No full text
    Many neurons receive excitatory glutamatergic input almost exclusively onto dendritic spines. In the absence of spines, the amplitudes and kinetics of excitatory postsynaptic potentials (EPSPs) at the site of synaptic input are highly variable and depend on dendritic location. We hypothesized that dendritic spines standardize the local geometry at the site of synaptic input, thereby reducing location-dependent variability of local EPSP properties. We tested this hypothesis using computational models of simplified and morphologically realistic spiny neurons that allow direct comparison of EPSPs generated on spine heads with EPSPs generated on dendritic shafts at the same dendritic locations. In all morphologies tested, spines greatly reduced location-dependent variability of local EPSP amplitude and kinetics, while having minimal impact on EPSPs measured at the soma. Spine-dependent standardization of local EPSP properties persisted across a range of physiologically relevant spine neck resistances, and in models with variable neck resistances. By reducing the variability of local EPSPs, spines standardized synaptic activation of NMDA receptors and voltage-gated calcium channels. Furthermore, spines enhanced activation of NMDA receptors and facilitated the generation of NMDA spikes and axonal action potentials in response to synaptic input. Finally, we show that dynamic regulation of spine neck geometry can preserve local EPSP properties following plasticity-driven changes in synaptic strength, but is inefficient in modifying the amplitude of EPSPs in other cellular compartments. These observations suggest that one function of dendritic spines is to standardize local EPSP properties throughout the dendritic tree, thereby allowing neurons to use similar voltage-sensitive postsynaptic mechanisms at all dendritic locations.This work was supported by National Institutes of Health grant R01 MH83806 (ATG), the National Health and Medical Research Council of Australia (GJS), and NIH grants NS11613 and DC00086 (NTC). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    Recent Developments in NEURON

    Get PDF
    Abstract. We describe four recent additions to NEURON's suite of graphical tools that make it easier for users to create and manage models: an enhancement to the Channel Builder that facilitates the specification and efficient simulation of stochastic channel models; an enhancement to the Cell Builder that enables the convenient specification of spatially non-uniform properties in anatomically complex cells; the Model Viewer, which presents a browsable and quickly understood summary of the properties of models of individual cells and networks; and the Import3D tool, which simplifies conversion of detailed morphometric data into computational models of neurons

    Abnormal Excitability of Oblique Dendrites Implicated in Early Alzheimer's: A Computational Study

    Get PDF
    The integrative properties of cortical pyramidal dendrites are essential to the neural basis of cognitive function, but the impact of amyloid beta protein (aβ) on these properties in early Alzheimer's is poorly understood. In animal models, electrophysiological studies of proximal dendrites have shown that aβ induces hyperexcitability by blocking A-type K+ currents (IA), disrupting signal integration. The present study uses a computational approach to analyze the hyperexcitability induced in distal dendrites beyond the experimental recording sites. The results show that back-propagating action potentials in the dendrites induce hyperexcitability and excessive calcium concentrations not only in the main apical trunk of pyramidal cell dendrites, but also in their oblique dendrites. Evidence is provided that these thin branches are particularly sensitive to local reductions in IA. The results suggest the hypothesis that the oblique branches may be most vulnerable to disruptions of IA by early exposure to aβ, and point the way to further experimental analysis of these actions as factors in the neural basis of the early decline of cognitive function in Alzheimer's

    Neuron Names: A Gene- and Property-Based Name Format, With Special Reference to Cortical Neurons

    Get PDF
    Precision in neuron names is increasingly needed. We are entering a new era in which classical anatomical criteria are only the beginning toward defining the identity of a neuron as carried in its name. New criteria include patterns of gene expression, membrane properties of channels and receptors, pharmacology of neurotransmitters and neuropeptides, physiological properties of impulse firing, and state-dependent variations in expression of characteristic genes and proteins. These gene and functional properties are increasingly defining neuron types and subtypes. Clarity will therefore be enhanced by conveying as much as possible the genes and properties in the neuron name. Using a tested format of parent-child relations for the region and subregion for naming a neuron, we show how the format can be extended so that these additional properties can become an explicit part of a neuron’s identity and name, or archived in a linked properties database. Based on the mouse, examples are provided for neurons in several brain regions as proof of principle, with extension to the complexities of neuron names in the cerebral cortex. The format has dual advantages, of ensuring order in archiving the hundreds of neuron types across all brain regions, as well as facilitating investigation of a given neuron type or given gene or property in the context of all its properties. In particular, we show how the format is extensible to the variety of neuron types and subtypes being revealed by RNA-seq and optogenetics. As current research reveals increasingly complex properties, the proposed approach can facilitate a consensus that goes beyond traditional neuron types

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Vitamin d status predicts 30 day mortality in hospitalised cats

    Get PDF
    Vitamin D insufficiency, defined as low serum concentrations of the major circulating form of vitamin D, 25 hydroxyvitamin D (25(OH)D), has been associated with the development of numerous infectious, inflammatory, and neoplastic disorders in humans. In addition, vitamin D insufficiency has been found to be predictive of mortality for many disorders. However, interpretation of human studies is difficult since vitamin D status is influenced by many factors, including diet, season, latitude, and exposure to UV radiation. In contrast, domesticated cats do not produce vitamin D cutaneously, and most cats are fed a commercial diet containing a relatively standard amount of vitamin D. Consequently, domesticated cats are an attractive model system in which to examine the relationship between serum 25(OH)D and health outcomes. The hypothesis of this study was that vitamin D status would predict short term, all-cause mortality in domesticated cats. Serum concentrations of 25(OH)D, together with a wide range of other clinical, hematological, and biochemical parameters, were measured in 99 consecutively hospitalised cats. Cats which died within 30 days of initial assessment had significantly lower serum 25(OH)D concentrations than cats which survived. In a linear regression model including 12 clinical variables, serum 25(OH)D concentration in the lower tertile was significantly predictive of mortality. The odds ratio of mortality within 30 days was 8.27 (95% confidence interval 2.54-31.52) for cats with a serum 25(OH)D concentration in the lower tertile. In conclusion, this study demonstrates that low serum 25(OH)D concentration status is an independent predictor of short term mortality in cats

    26th Annual Computational Neuroscience Meeting (CNS*2017): Part 3 - Meeting Abstracts - Antwerp, Belgium. 15–20 July 2017

    Get PDF
    This work was produced as part of the activities of FAPESP Research,\ud Disseminations and Innovation Center for Neuromathematics (grant\ud 2013/07699-0, S. Paulo Research Foundation). NLK is supported by a\ud FAPESP postdoctoral fellowship (grant 2016/03855-5). ACR is partially\ud supported by a CNPq fellowship (grant 306251/2014-0)

    Computer Simulation Methods for Neurons

    No full text
    This article focuses on a single but critical part of the process of creating a computer program for neural simulation: the numerical methods for solving the cable equation with voltage dependent channel conductances. We concentrate on electrical signaling for two reasons. First, many models that include electrical signals while ignoring chemical signals have proven useful. Second, both electrical and chemical signaling are susceptible to the same computational strategies, since both are examples of the broad class of reactive diffusion problems (Oran and Boris 1987; Carnevale and Rosenthal 1992a,b) and are described by parabolic partial differential equations. We attempt to provide an intuitive rationale for the methods. The only mathematical prerequisite is some algebra and two concepts from first year calculus that are used very intuitively: differentiation and Taylor&apos;s theorem. Of the many previous articles that discuss numerical methods for solving the cable equation, Mascagni&apos;s chapter in Koch and Segev (1989) is notable for a reasonably complete explanation and bibliography. Douglas (1961) gives a fairly rigorous account of numerical methods for solving parabolic partial differential equations. Hines (1984) discusses special techniques for fast simulations of neurons. A textbook with good general coverage of numerical methods for differential equations has been written by Dahlquist and Bjo rck (1974) The Basic Approac

    Recent Developments in NEURON

    No full text
    We describe four recent additions to NEURON's suite of graphical tools that make it easier for users to create and manage models: an enhancement to the Channel Builder that facilitates the specification and efficient simulation of stochastic channel model
    corecore